Foundry-networks OSI Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Foundry-networks OSI. Foundry Networks OSI User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Installation Guide

Foundry EdgeIron 4802CFInstallation Guide2100 Gold StreetP.O. Box 649100San Jose, CA 95164-9100Tel 408.586.1700Fax 408.586.1900www.foundrynetworks.com

Pagina 2

CONTENTS10 © 2003 Foundry Networks, Inc. February 20031000 Mbps Gigabit Ethernet Collision Domain . . . . . . . . . . . . . 3-6100 Mbps Fast Ethernet

Pagina 3 - COMPLIANCES

CONTENTSFebruary 2003 © 2003 Foundry Networks, Inc. 11Adjusting Existing Category 5 Cabling to Run 1000BASE-T . . . . . . . . . . . . . . . . . . . .

Pagina 4 - Immunity:

CONTENTS12 © 2003 Foundry Networks, Inc. February 2003

Pagina 5 - Taiwan BSMI Class A

February 2003 © 2003 Foundry Networks, Inc. 1-1CHAPTER 1ABOUT THIS GUIDEAudienceThis guide is for system administrators with a working knowledge of ne

Pagina 6 - Safety Compliance

EDGEIRON 4802CF INSTALLATION GUIDE1-2 © 2003 Foundry Networks, Inc. February 2003Web AccessPoint your browser to the following URL: http://www.foundry

Pagina 7 - OMPLIANCES

February 2003 © 2003 Foundry Networks, Inc. 2-1CHAPTER 2ABOUT THEEDGEIRON 4802CFOverviewFoundry’s EdgeIron 4802CF is an intelligent Fast Ethernet swit

Pagina 8

ABOUT THE EDGEIRON 4802CF2-2 © 2003 Foundry Networks, Inc. February 2003Switch ArchitectureThe EdgeIron 4802CF employs a wire-speed, non-blocking swit

Pagina 9

DESCRIPTION OF HARDWAREFebruary 2003 © 2003 Foundry Networks, Inc. 2-3Description of Hardware10BASE-T/100BASE-TX PortsThese are dual-speed RJ-45 ports

Pagina 10

ABOUT THE EDGEIRON 4802CF2-4 © 2003 Foundry Networks, Inc. February 2003Status LEDs The LEDs, which are located on the front panel for easy viewing, a

Pagina 11 - Glossary

DESCRIPTION OF HARDWAREFebruary 2003 © 2003 Foundry Networks, Inc. 2-5FDX*(all ports)On Green Port is operating in full-duplex mode.Off Port is operat

Pagina 12

Copyright © 2003 Foundry Networks, Inc. All rights reserved. No part of this work may be reproduced in any form or by any means – graphic, electronic

Pagina 13 - How to Get Help

ABOUT THE EDGEIRON 4802CF2-6 © 2003 Foundry Networks, Inc. February 2003Optional Redundant Power UnitFoundry provides an optional Redundant Power Unit

Pagina 14 - Related Publications

FEATURES AND BENEFITSFebruary 2003 © 2003 Foundry Networks, Inc. 2-7Features and BenefitsConnectivity◆ 48 dual-speed ports for easy Fast Ethernet inte

Pagina 15 - Overview

ABOUT THE EDGEIRON 4802CF2-8 © 2003 Foundry Networks, Inc. February 2003◆ Includes support for an optional Redundant Power Unit◆ Desktop or rack-mount

Pagina 16

February 2003 © 2003 Foundry Networks, Inc. 3-1CHAPTER 3NETWORK PLANNINGIntroduction to SwitchingA network switch allows simultaneous transmission of

Pagina 17 - Description of Hardware

NETWORK PLANNING3-2 © 2003 Foundry Networks, Inc. February 2003Application ExamplesThe EdgeIron 4802CF is not only designed to segment your network, b

Pagina 18

APPLICATION EXAMPLESFebruary 2003 © 2003 Foundry Networks, Inc. 3-3Central Wiring ClosetWith 50 parallel bridging ports (i.e., 50 distinct collision d

Pagina 19 - ESCRIPTION

NETWORK PLANNING3-4 © 2003 Foundry Networks, Inc. February 2003Remote Connections with Fiber CableFiber optic technology allows for longer cabling tha

Pagina 20

APPLICATION EXAMPLESFebruary 2003 © 2003 Foundry Networks, Inc. 3-5Making VLAN ConnectionsVLANs can be based on port groups, or each data frame can be

Pagina 21 - Features and Benefits

NETWORK PLANNING3-6 © 2003 Foundry Networks, Inc. February 2003Connectivity RulesWhen adding hubs (repeaters) to your network, please follow the stand

Pagina 22

CONNECTIVITY RULESFebruary 2003 © 2003 Foundry Networks, Inc. 3-7100 Mbps Fast Ethernet Collision DomainMaximum Fast Ethernet Cable Distance10 Mbps Et

Pagina 23 - Introduction to Switching

February 2003 © 2003 Foundry Networks, Inc. 3COMPLIANCESFCC - Class AThis equipment generates, uses, and can radiate radio frequency energy and, if no

Pagina 24 - Application Examples

NETWORK PLANNING3-8 © 2003 Foundry Networks, Inc. February 2003Application Notes1. Full-duplex operation only applies to point-to-point access (such a

Pagina 25 - Central Wiring Closet

February 2003 © 2003 Foundry Networks, Inc. 4-1CHAPTER 4INSTALLING THE SWITCHSelecting a SiteEdgeIron 4802CF units can be mounted in a standard 19-inc

Pagina 26

INSTALLING THE SWITCH4-2 © 2003 Foundry Networks, Inc. February 2003Equipment ChecklistAfter unpacking the EdgeIron 4802CF, check the contents to be s

Pagina 27 - Making VLAN Connections

MOUNTINGFebruary 2003 © 2003 Foundry Networks, Inc. 4-3MountingAn EdgeIron 4802CF unit can be mounted in a standard 19-inch equipment rack or on a des

Pagina 28 - Connectivity Rules

INSTALLING THE SWITCH4-4 © 2003 Foundry Networks, Inc. February 2003To rack-mount devices:1. Attach the brackets to the device using the screws provid

Pagina 29 - ONNECTIVITY

MOUNTINGFebruary 2003 © 2003 Foundry Networks, Inc. 4-53. If installing a single switch only, turn to “Connecting to a Power Source” at the end of thi

Pagina 30 - Application Notes

INSTALLING THE SWITCH4-6 © 2003 Foundry Networks, Inc. February 2003Connecting to a Power SourceTo connect a device to a power source:1. Insert the po

Pagina 31 - NSTALLING

February 2003 © 2003 Foundry Networks, Inc. 5-1CHAPTER 5MAKING NETWORKCONNECTIONSConnecting Network DevicesThe EdgeIron 4802CF is designed to intercon

Pagina 32 - Equipment Checklist

MAKING NETWORK CONNECTIONS5-2 © 2003 Foundry Networks, Inc. February 2003Note: If auto-negotiation is disabled for an RJ-45 port, the auto-MDI/MDI-X p

Pagina 33 - Mounting

TWISTED-PAIR DEVICESFebruary 2003 © 2003 Foundry Networks, Inc. 5-3Notes: 1. When connected to a shared collision domain (such as a hub with multiple

Pagina 34

EDGEIRON 4802CF INSTALLATION GUIDE4 © 2003 Foundry Networks, Inc. February 2003Warning: Do not plug a phone jack connector in the RJ-45 port. This may

Pagina 35 - Desktop or Shelf Mounting

MAKING NETWORK CONNECTIONS5-4 © 2003 Foundry Networks, Inc. February 2003Figure 5-2. Wiring Closet Connections Equipment Rack(side view)SwitchPatch P

Pagina 36 - Connecting to a Power Source

February 2003 © 2003 Foundry Networks, Inc. A-1APPENDIX ATROUBLESHOOTINGDiagnosing Switch Indicators Power and Cooling ProblemsIf the power indicator

Pagina 37 - ONNECTIONS

TROUBLESHOOTINGA-2 © 2003 Foundry Networks, Inc. February 2003check for loose power connections, power losses or surges at the power outlet, and verif

Pagina 38

February 2003 © 2003 Foundry Networks, Inc. B-1APPENDIX BCABLESSpecifications Cable Types and SpecificationsCable Type Max. Length Connector10BASE-T

Pagina 39 - Wiring Closet Connections

CABLESB-2 © 2003 Foundry Networks, Inc. February 2003Twisted-Pair Cable and Pin AssignmentsCaution: DO NOT plug a phone jack connector into any RJ-45

Pagina 40

TWISTED-PAIR CABLE AND PIN ASSIGNMENTSFebruary 2003 © 2003 Foundry Networks, Inc. B-3100BASE-TX/10BASE-T Pin AssignmentsWith 100BASE-TX/10BASE-T cable

Pagina 41 - ROUBLESHOOTING

CABLESB-4 © 2003 Foundry Networks, Inc. February 20031000BASE-T Pin Assignments1000BASE-T ports switch support automatic MDI/MDI-X operation, so you c

Pagina 42 - In-Band Access

TWISTED-PAIR CABLE AND PIN ASSIGNMENTSFebruary 2003 © 2003 Foundry Networks, Inc. B-51000BASE-T Cable RequirementsAll Category 5 UTP cables that are u

Pagina 43 - Specifications

CABLESB-6 © 2003 Foundry Networks, Inc. February 2003Console Port Pin AssignmentsThe DB-9 serial port on the switch’s rear panel is used to connect to

Pagina 44

CONSOLE PORT PIN ASSIGNMENTSFebruary 2003 © 2003 Foundry Networks, Inc. B-7Console Port to 25-Pin DTE Port on PCSwitch’s 9-Pin Serial PortNull Modem P

Pagina 45

COMPLIANCESFebruary 2003 © 2003 Foundry Networks, Inc. 5Taiwan BSMI Class AAustralia AS/NZS 3548 (1995) - Class AContact Foundry Networks at:Foundry N

Pagina 46 - 1000BASE-T Pin Assignments

CABLESB-8 © 2003 Foundry Networks, Inc. February 2003

Pagina 47

February 2003 © 2003 Foundry Networks, Inc. C-1APPENDIX CSPECIFICATIONSPhysical CharacteristicsPorts48 10BASE-T/100BASE-TX, with auto-negotiationTwo 1

Pagina 48 - Console Port Pin Assignments

SPECIFICATIONSC-2 © 2003 Foundry Networks, Inc. February 2003TemperatureOperating: 0 to 50 °C (32 to 122 °F)Storage: -40 to 70 °C (-40 to 158 °F)Humid

Pagina 49 - SSIGNMENTS

SWITCH FEATURESFebruary 2003 © 2003 Foundry Networks, Inc. C-3Switch FeaturesSpanning Tree ProtocolForwarding ModeStore-and-forwardFlow ControlFull Du

Pagina 50

SPECIFICATIONSC-4 © 2003 Foundry Networks, Inc. February 2003Management FeaturesIn-Band ManagementTelnet, Web-based HTTP, or SNMP managerOut-of-Band M

Pagina 51 - PECIFICATIONS

COMPLIANCESFebruary 2003 © 2003 Foundry Networks, Inc. C-5CompliancesCE MarkEmissionsFCC Class AIndustry Canada Class AEN55022 (CISPR 22) Class AEN 61

Pagina 52 - °C (-40 to 158 °F)

SPECIFICATIONSC-6 © 2003 Foundry Networks, Inc. February 2003

Pagina 53 - Switch Features

February 2003 © 2003 Foundry Networks, Inc. Glossary-1GLOSSARY10BASE-TIEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3, 4, o

Pagina 54 - Standards

GLOSSARYGlossary-2 © 2003 Foundry Networks, Inc. February 2003BandwidthThe difference between the highest and lowest frequencies available for network

Pagina 55 - Compliances

GLOSSARYFebruary 2003 © 2003 Foundry Networks, Inc. Glossary-3Gigabit EthernetA 1000 Mbps network communication system based on Ethernet and the CSMA/

Pagina 56

EDGEIRON 4802CF INSTALLATION GUIDE6 © 2003 Foundry Networks, Inc. February 2003Safety ComplianceWarning: Fiber Optic Port SafetyAvertissment: Ports po

Pagina 57

GLOSSARYGlossary-4 © 2003 Foundry Networks, Inc. February 2003LAN SegmentSeparate LAN or collision domain.LEDLight emitting diode used for monitoring

Pagina 58

GLOSSARYFebruary 2003 © 2003 Foundry Networks, Inc. Glossary-5Transmission Control Protocol/Internet Protocol (TCP/IP)Protocol suite that includes TCP

Pagina 59

GLOSSARYGlossary-6 © 2003 Foundry Networks, Inc. February 2003

Pagina 60

February 2003 © 2003 Foundry Networks, Inc. Index-1Numerics10 Mbps connectivity rules 3-71000 Mbps connectivity rules 3-61000BASE-LXfiber cable length

Pagina 61

INDEXIndex-2 © 2003 Foundry Networks, Inc. February 2003IIEEE 802.3x flow control 2-3IGMP 2-2indicators, LED 2-4installationconnecting devices to the

Pagina 62

INDEXFebruary 2003 © 2003 Foundry Networks, Inc. Index-3RMON 2-2routing applications 3-8RPUconnecting 4-6installing in a rack 4-5installing on a deskt

Pagina 63

INDEXIndex-4 © 2003 Foundry Networks, Inc. February 2003

Pagina 64

COMPLIANCESFebruary 2003 © 2003 Foundry Networks, Inc. 7Wichtige Sicherheitshinweise (Germany)1. Bitte lesen Sie diese Hinweise sorgfältig durch.2. He

Pagina 65

EDGEIRON 4802CF INSTALLATION GUIDE8 © 2003 Foundry Networks, Inc. February 2003

Pagina 66

February 2003 © 2003 Foundry Networks, Inc. 9CONTENTS1 About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1Audience . . .

Comentarios a estos manuales

Sin comentarios